Functions implemented by the control unit
- Control of the supply air and the screw or press conveyor.
- Control of the heating pump and the hot water pump Possibility of connecting a room controller Weekly control (optional)
Equipment of the control unit
- LCD display
- Heating water temperature sensor
- Temperature sensor for hot water
- Temperature sensor on the screw (fuse)
- thermal fuse
- Housing made of high-quality, temperature-resistant materials
- Panel housing for installation on the boiler
- Possibility of mounting in the OM-01 housing
Technical specifications
- Power supply V 230V/50Hz +/-10%
- Permissible power consumption of the control unit W 7
- Ambient temperature °C 5÷50
- Load of the output of the heating pump A 0.5
- Load on the output of the hot water pump A 0.5
- Fan output load A 0.6
- Temperature measurement range °C 0÷85
- Measurement accuracy °C 1
- Temperature setting range °C 40÷80
- Temperature sensor resistance °C -25÷100
- Initial load of feeder A 2
- Fuse A 6.3